Logger Script
   
 
¼ÒÀ½°è, Áøµ¿°è
Á¶µµ°è,±¤·®°è,CHROMA METER,ÈÖµµ°è
Àϻ緮/±¤Åõ°úÀ² ÃøÁ¤±â
žçÀüÁö,ž籤¸ðµâ È¿À² ºÐ¼®±â
ȸÀü°è, ½ºÆ®·Îº¸½ºÄÚÇÁ
dz¼Ó°è,dz·®Ç³¼Ó°è,¿­¼±½Ädz·®Ç³¼Ó°è
¿Âµµ°è,¿Âµµ¼¾¼­,¿Â½Àµµ°è,³ëÁ¡°è,
µ¥ÀÌÅͱâ·Ï°è(µ¥ÀÌÅͷΰÅ)
WBGTÃøÁ¤±â,±â¾Ð°è
¹èÅ͸®Å×½ºÅÍ
ÀüÀÚÆÄ,Á¤Àü±â,°¡¿ì½º¸ÞŸ,Ç¥¸éÀúÇ×
Ķ¸®ºê·¹ÀÌÅÍ(CALIBRATOR)
»öÂ÷°è,ºÐ±¤±¤µµ°è,±¤Åðè,HAZE METER
ÆÄƼŬī¿îÅÍ(PARTICLE COUNTER),ºÐÁøÃøÁ¤±â
Àü±âÀüÀÚ°èÃø±â
´çµµ°è,¿°ºÐ°è,±¼Àý°è
»ê¾÷¿ë³»½Ã°æ
Çʸ§/À¯¸®Åõ°úÀ²ÃøÁ¤±â,UV±¤·®°è
µµ¸·µÎ²²ÃøÁ¤±â,ÃÊÀ½Æĵβ²ÃøÁ¤±â
°æµµ°è
¼öºÐÃøÁ¤±â
°¡½ºÃøÁ¤±â,³¿»õÃøÁ¤±â
¼öÁúÃøÁ¤±â
ÇÉȦŽÁö±â(Holiday Detector)
Ǫ½¬Ç®°ÔÀÌÁö,ÅټǸÞŸ,ÅäÅ©Å×½ºÅÍ
È®´ë°æ,¸¶ÀÌÅ©·Î½ºÄÚÇÁ,Á¶¸íÈ®´ë°æ
Àû¿Ü¼± ¿­È­»ó Ä«¸Þ¶ó
Å©·¢(±Õ¿­)ÃøÁ¤±â
À½ÀÌ¿ÂÃøÁ¤±â/¹æ»ç¼±·®ÃøÁ¤±â
ÃÊÀ½ÆÄŽ»ó±â
MIC Meter Industrial Company Á¦Ç°
REK Á¦Ç°
±âŸ
½ÅÁ¦Ç°
Ãßõ»óÇ°
°øµ¿ÁÖÅà °ü¸®±â±¸ Àåºñ
¹ýÁ¤µî·ÏÀåºñ(Çü½Ä½ÂÀÎÀåºñ)
HOME > Á¦Ç°¼Ò°³
 
TES-3100/3101/3102 Áøµ¿°è
 
- Wide range of measurement applications supported by selecting different accelerometers
- Backup function instantly reactivates previous settings at next power-on
- Maximum/Minimum record function
- Manual memory stores up to 99 data
- Headphone output for detecting noise in machine components
- USB interface allows transfer of saved data to PC (3101,3102)
-Auto memory micro SD card 4GB(Maximum capacity 32GB can be used)(3101,3102)





- Àû¿ëºÐ¾ß
Industrial hygiene investigations (»ê¾÷ À§»ý Á¶»ç)
Industrial machinery check-ups (»ê¾÷ ±â°è)
Manufacturibg QA (Á¶ÀÛ ºÐ¾ß)
 
 
 
 
Piezoelectric Acclerometer (PA-01)
Sensitivity
5§Æ/(§¾)(¡¾10%)
Acceleration range
200§¾
Amplitude nonlinerity
¡¾1%
Frequency response
5§Ô-10§Õ(¡¾10%),10§Õ-15§Õ(¡¾3dB)
Resonance freqency
27§Õ
Transverse sensitivity
¡Â5%
Dimensoins/Weight
46(H)x19(D)§® / 46g
Piezoelectric Acclerometer (PA-02) (3102)
Sensitivity
10§Æ/(§¾)(¡¾10%)
Acceleration range
100§¾
Amplitude nonlinerity
¡¾1%
Frequency response
5§Ô-5§Õ(¡¾10%),5§Õ-12§Õ(¡¾3dB)
Resonance freqency
20§Õ
Transverse sensitivity
¡Â5%
Dimensoins/Weight
52(H)x22(D)§® / 72g
Measurement range (using PA-01 or PA-02)
ACC (Acceleration)
0.02 200§¾ / EQ PEAK 1Hz-5kHz
VEL (Velocity)
0.3-1000mm/s / RMS 3Hz-1kHz
0.1-1000mm/s / RMS 10§Ô-1§Õ
DISP (Displacement)
0.02-100§® / EQ PEAK 3§Ô-500§Ô
0.001-100§® / EQ PEAK 10§Ô-500§Ô
Frequency range
ACC (Acceleration)
3Hz-1§Õ,3Hz-5§Õ,1Hz-100§Ô,3Hz-20§Õ
VEL (Velocity)
10Hz-1§Õ,3Hz-1§Õ,
DISP (Displacement)
10Hz-500§Ô,3Hz-500§Ô
Measurement full-sacle range
For accelerometer PA-01 and
accelerometers with sensitivity
1.0 9.9§Æ/(§¾)
ACC (Acceleration)
1,10,100,1000§¾
VEL (Velocity)
10,100,1000mm/s
DISP (Displacement)
0.1,1,10,100§®
Indication characteristics
Acceleration
RMS, EQ PEAK
Velocity
RMS, EQ PEAK
Displacement
RMS, EQ PEAK,EQ p-p
Gain calibrtion
Setting range
0.10-0.99, 1.0.-9.9, 10-99§Æ/(§¾)





¼¼ºÎ»çÇ×
³» ¿ë
Measurement range
- °¡¼Óµµ (ACC) £º0.02¡­200m/s£² EQ PEAK 1§Ô ~ 5§Õ

- ¼Óµµ (VEL) £º0.3¡­1000mm/s RMS 3§Ô ~ 1§Õ
                      0.1 ~ 1000mm/s RMS 10§Ô ~ 1§Õ

- º¯À§ (DISP) £º0.02¡­100mm/s EQ PEAK 3§Ô ~ 500§Ô
                       0.001 ~ 100mm/s EQ PEAK 10§Ô ~ 500§Ô
Frequency range
- °¡¼Óµµ (ACC) £º3Hz~1kHz,3Hz~5kHz,1Hz~100Hz,3Hz¡­20kHz
- ¼Óµµ(VEL)    £º10Hz¡­1kHz, 3§Ô ~ 1§Õ
- º¯À§(DISP)   £º10Hz¡­500Hz, 3§Ô ~ 500§Ô
Measurement range settings

- °¡¼Óµµ (ACC)£º1, 10, 100, 1000m/s2

¼Óµµ (VEL)  £º10, 100, 1000mm/s

º¯À§ (DISP) £º0.1, 1, 10,100mm/s

µð½ºÇ÷¹ÀÌƯ¼º
- °¡¼Óµµ (ACC) £ºRMS, EQ Peak
- ¼Óµµ(VEL)   £ºRMS, EQ Peak
- º¯À§ (DISP)  £ºRMS, EQ Peak, EQ p-p       
Time constant
of rms processing
1 second

Data memory &

Auto
memory(3101,3102)

Maximum 99 data(01 ~ 99) can be stored by manually


Micro SD CARD 4GB(Maximum 99 blocks and 32GB)
 
Gain calibration
Setting range:

After setting the accelerometer sensitivity, calibration is performed
to provide gain
0.10 - 0.99, 1.0 - 9.9, 10 - 99 §Æ/(§½©÷)

Overlosd indication
"OVER" flashing shown in LCD display
Battery status
indication
4 - segment display
Display accuracy
(electrical characteristics)
Acceleration(ACC): Range full-scale¡¾2% (159.2 §Ô)
Velocity (VEL): Range full-scale¡¾3% (159.2 §Ô)
Displacement (DISP): Range full-scale¡¾5% (159.2 §Ô)
Overall accuracy
(in combination with PA-01 or PA-02)
Acceleration(ACC): Range full-scale¡¾2% (159.2 §Ô)
Headphone output
Vibration sound monitor
Ambient conditions
-10¡É ~ +50¡É, max.90% RH
Power requirements
Four IEC R6 size AA batterties or AC adaptor(optional)
Power consumption
Approx.60mA (6V, backlight off)
Battery life
Zinc-carbon batte (R6KG): Approx. 8 hours
Alkaline batteries (LR6): Approx. 21 hours
Nickel-metal hydride batteries (HR6): eneloop xx Approx. 23 hours
Dimensions
169§®(L)¡¿78§®(W)¡¿40§®(D) (Maximum)
158§®(L)¡¿78§®(W)¡¿40§®(D) (without protruding parts)   
Weight
Approx.273g(¹èÅ͸® Æ÷ÇÔ)
Supplied accessories
Piezoelectric accelerometer: PA-01 x 1,PA-02 x 1(3102)
Accessories for accelerometer:Curled cable VA-02x1
                                             Magnet attachment VA-01 x 1
IEC R6 batteries zinc-carbon x 4       
Instruction manual x 1
PA-01 calibration chart x 1  
PA-02 calibration chart x 1(3102)  
CD softwarex x 1 (3101,3102)
Micro-USB cable x 1 (3101,3102)    
Optional accessories
AC adapter
M5 x 0.8 screw VA-04
Hex flat attachment VA-05
Rod attachment VA-06