TES-3100/3101/3102 Áøµ¿°è |
|
|
- Wide range of measurement applications supported by selecting different accelerometers
- Backup function instantly reactivates previous settings at next power-on
- Maximum/Minimum record function
- Manual memory stores up to 99 data
- Headphone output for detecting noise in machine components
- USB interface allows transfer of saved data to PC (3101,3102)
-Auto memory micro SD card 4GB(Maximum capacity 32GB can be used)(3101,3102)
- Àû¿ëºÐ¾ß
Industrial hygiene investigations (»ê¾÷ À§»ý Á¶»ç)
Industrial machinery check-ups (»ê¾÷ ±â°è)
Manufacturibg QA (Á¶ÀÛ ºÐ¾ß)
|
|
|
|
|
|
|
|
Piezoelectric Acclerometer (PA-01)
|
Sensitivity
|
5§Æ/(§¾)(¡¾10%)
|
Acceleration range
|
200§¾
|
Amplitude nonlinerity
|
¡¾1%
|
Frequency response
|
5§Ô-10§Õ(¡¾10%),10§Õ-15§Õ(¡¾3dB)
|
Resonance freqency
|
27§Õ
|
Transverse sensitivity
|
¡Â5%
|
Dimensoins/Weight
|
46(H)x19(D)§® / 46g
|
Piezoelectric Acclerometer (PA-02) (3102)
|
Sensitivity
|
10§Æ/(§¾)(¡¾10%)
|
Acceleration range
|
100§¾
|
Amplitude nonlinerity
|
¡¾1%
|
Frequency response
|
5§Ô-5§Õ(¡¾10%),5§Õ-12§Õ(¡¾3dB)
|
Resonance freqency
|
20§Õ
|
Transverse sensitivity
|
¡Â5%
|
Dimensoins/Weight
|
52(H)x22(D)§® / 72g
|
Measurement range (using PA-01 or PA-02)
|
ACC (Acceleration)
|
0.02 – 200§¾ / EQ PEAK 1Hz-5kHz
|
VEL (Velocity)
|
0.3-1000mm/s / RMS 3Hz-1kHz
0.1-1000mm/s / RMS 10§Ô-1§Õ
|
DISP (Displacement)
|
0.02-100§® / EQ PEAK 3§Ô-500§Ô
0.001-100§® / EQ PEAK 10§Ô-500§Ô
|
Frequency range
|
ACC (Acceleration)
|
3Hz-1§Õ,3Hz-5§Õ,1Hz-100§Ô,3Hz-20§Õ
|
VEL (Velocity)
|
10Hz-1§Õ,3Hz-1§Õ,
|
DISP (Displacement)
|
10Hz-500§Ô,3Hz-500§Ô
|
Measurement full-sacle range
|
For accelerometer PA-01 and
accelerometers with sensitivity
|
1.0 – 9.9§Æ/(§¾)
|
ACC (Acceleration)
|
1,10,100,1000§¾
|
VEL (Velocity)
|
10,100,1000mm/s
|
DISP (Displacement)
|
0.1,1,10,100§®
|
Indication characteristics
|
Acceleration
|
RMS, EQ PEAK
|
Velocity
|
RMS, EQ PEAK
|
Displacement
|
RMS, EQ PEAK,EQ p-p
|
Gain calibrtion
|
Setting range
|
0.10-0.99, 1.0.-9.9, 10-99§Æ/(§¾)
|
¼¼ºÎ»çÇ×
|
³» ¿ë
|
Measurement range
|
- °¡¼Óµµ (ACC) £º0.02¡200m/s£² EQ PEAK 1§Ô ~ 5§Õ
- ¼Óµµ (VEL) £º0.3¡1000mm/s RMS 3§Ô ~ 1§Õ
0.1 ~ 1000mm/s RMS 10§Ô ~ 1§Õ
- º¯À§ (DISP) £º0.02¡100mm/s EQ PEAK 3§Ô ~ 500§Ô
0.001 ~ 100mm/s EQ PEAK 10§Ô ~ 500§Ô
|
Frequency range
|
- °¡¼Óµµ (ACC) £º3Hz~1kHz,3Hz~5kHz,1Hz~100Hz,3Hz¡20kHz
- ¼Óµµ(VEL) £º10Hz¡1kHz, 3§Ô ~ 1§Õ
- º¯À§(DISP) £º10Hz¡500Hz, 3§Ô ~ 500§Ô
|
Measurement range settings
|
- °¡¼Óµµ (ACC)£º1, 10, 100, 1000m/s2
- ¼Óµµ (VEL) £º10, 100, 1000mm/s
- º¯À§ (DISP) £º0.1, 1, 10,100mm/s
|
µð½ºÇ÷¹ÀÌƯ¼º
|
- °¡¼Óµµ (ACC) £ºRMS, EQ Peak
- ¼Óµµ(VEL) £ºRMS, EQ Peak
- º¯À§ (DISP) £ºRMS, EQ Peak, EQ p-p
|
Time constant
of rms processing
|
1 second
|
Data memory &
|
Maximum 99 data(01 ~ 99) can be stored by manually
Micro SD CARD 4GB(Maximum 99 blocks and 32GB)
|
Gain calibration
Setting range:
|
After setting the accelerometer sensitivity, calibration is performed
to provide gain
0.10 - 0.99, 1.0 - 9.9, 10 - 99 §Æ/(§½©÷)
|
Overlosd indication
|
"OVER" flashing shown in LCD display
|
Battery status
indication
|
4 - segment display
|
Display accuracy
(electrical characteristics)
|
Acceleration(ACC): Range full-scale¡¾2% (159.2 §Ô)
Velocity (VEL): Range full-scale¡¾3% (159.2 §Ô)
Displacement (DISP): Range full-scale¡¾5% (159.2 §Ô)
|
Overall accuracy
(in combination with PA-01 or PA-02)
|
Acceleration(ACC): Range full-scale¡¾2% (159.2 §Ô)
|
Headphone output
|
Vibration sound monitor
|
Ambient conditions
|
-10¡É ~ +50¡É, max.90% RH
|
Power requirements
|
Four IEC R6 size AA batterties or AC adaptor(optional)
|
Power consumption
|
Approx.60mA (6V, backlight off)
|
Battery life
|
Zinc-carbon batte (R6KG): Approx. 8 hours
Alkaline batteries (LR6): Approx. 21 hours
Nickel-metal hydride batteries (HR6): eneloop xx Approx. 23 hours
|
Dimensions
|
169§®(L)¡¿78§®(W)¡¿40§®(D) (Maximum)
158§®(L)¡¿78§®(W)¡¿40§®(D) (without protruding parts)
|
Weight
|
Approx.273g(¹èÅ͸® Æ÷ÇÔ)
|
Supplied accessories
|
Piezoelectric accelerometer: PA-01 x 1,PA-02 x 1(3102)
Accessories for accelerometer:Curled cable VA-02x1
Magnet attachment VA-01 x 1
IEC R6 batteries zinc-carbon x 4
Instruction manual x 1
PA-01 calibration chart x 1
PA-02 calibration chart x 1(3102)
CD softwarex x 1 (3101,3102)
Micro-USB cable x 1 (3101,3102)
|
Optional accessories
|
AC adapter
M5 x 0.8 screw VA-04
Hex flat attachment VA-05
Rod attachment VA-06
|
|
|
|
| |
|