Logger Script
   
 
¼ÒÀ½°è, Áøµ¿°è
Á¶µµ°è,±¤·®°è,CHROMA METER,ÈÖµµ°è
Àϻ緮/±¤Åõ°úÀ² ÃøÁ¤±â
žçÀüÁö,ž籤¸ðµâ È¿À² ºÐ¼®±â
ȸÀü°è, ½ºÆ®·Îº¸½ºÄÚÇÁ
dz¼Ó°è,dz·®Ç³¼Ó°è,¿­¼±½Ädz·®Ç³¼Ó°è
¿Âµµ°è,¿Âµµ¼¾¼­,¿Â½Àµµ°è,³ëÁ¡°è,
µ¥ÀÌÅͱâ·Ï°è(µ¥ÀÌÅͷΰÅ)
WBGTÃøÁ¤±â,±â¾Ð°è
¹èÅ͸®Å×½ºÅÍ
ÀüÀÚÆÄ,Á¤Àü±â,°¡¿ì½º¸ÞŸ,Ç¥¸éÀúÇ×
͏®ºê·¹ÀÌÅÍ(CALIBRATOR)
»öÂ÷°è,ºÐ±¤±¤µµ°è,±¤Åðè,HAZE METER
ÆÄƼŬī¿îÅÍ(PARTICLE COUNTER),ºÐÁøÃøÁ¤±â
Àü±âÀüÀÚ°èÃø±â
´çµµ°è,¿°ºÐ°è,±¼Àý°è
»ê¾÷¿ë³»½Ã°æ
Çʸ§/À¯¸®Åõ°úÀ²ÃøÁ¤±â,UV±¤·®°è
µµ¸·µÎ²²ÃøÁ¤±â,ÃÊÀ½ÆÄµÎ²²ÃøÁ¤±â
°æµµ°è
¼öºÐÃøÁ¤±â
°¡½ºÃøÁ¤±â,³¿»õÃøÁ¤±â
¼öÁúÃøÁ¤±â
ÇÉȦŽÁö±â(Holiday Detector)
Ǫ½¬Ç®°ÔÀÌÁö,ÅټǸÞŸ,ÅäÅ©Å×½ºÅÍ
È®´ë°æ,¸¶ÀÌÅ©·Î½ºÄÚÇÁ,Á¶¸íÈ®´ë°æ
Àû¿Ü¼± ¿­È­»ó Ä«¸Þ¶ó
Å©·¢(±Õ¿­)ÃøÁ¤±â
À½ÀÌ¿ÂÃøÁ¤±â/¹æ»ç¼±·®ÃøÁ¤±â
ÃÊÀ½ÆÄŽ»ó±â
MIC Meter Industrial Company Á¦Ç°
REK Á¦Ç°
±âŸ
½ÅÁ¦Ç°
Ãßõ»óǰ
°øµ¿ÁÖÅà °ü¸®±â±¸ Àåºñ
¹ýÁ¤µî·ÏÀåºñ(Çü½Ä½ÂÀÎÀåºñ)
HOME > Á¦Ç°¼Ò°³
 
HAL-HPC301 ºÐÁøÃøÁ¤±â(Particle Mass Counter)
 
- 3°³ ÆÄƼŬ »çÀÌÁî(0.3, 0.5, 0.7, 1.0, 2.0, 2.5, 5, 10, 15¥ìm Áß ¼±Åà °¡´É) µ¿½ÃÃøÁ¤
- ÃøÁ¤ Áö¿¬½Ã°£, »ùÇøµ ŸÀÓ, ÀÎÅ͹ú ŸÀÓ Á¶Á¤ °¡´É
- µ¥ÀÌÅÍ ´Ù¿î·Îµå¸¦ À§ÇÑ USB ÀÎÅÍÆäÀ̽º(¼ÒÇÁÆ®¿þ¾î Á¦°ø)
- ÇѰèÄ¡ °æ°í ±â´É: FED, ISO ±ÔÁ¤ Áؼö
- ¿¡·¯ »óÅ ǥ½Ã: ¼¾¼­ »óÅÂ¿Í ¹èÅ͸® ÃæÀü »óÅ ÀÚµ¿ Á¡°Ë
- 5000°³ ÀÌ»óÀÇ µ¥ÀÌÅÍ ÀúÀå °¡´É
- Æò±Õ°ª ÃøÁ¤
- 260°³ÀÇ À§Ä¡¹øÈ£(location) ¶óº§
- 6½Ã°£ ÀÌ»ó ÀÛµ¿ °¡´É
- ¿ÜºÎ ¿Âµµ, »ó´ë½Àµµ, ¾Ð·Â ÃøÁ¤(¿É¼Ç)
- ºí·çÅõ½º ¹«¼± ÇÁ¸°ÆÃ(¿É¼Ç)

- Àû¿ëºÐ¾ß
- Clean environment monitoring
- Indoor/outdoor air quality
- Test/Check filter seal and efficiency
- Trace contamination source
- Analysis of particle size distribution etc.
 
 
 
Á¦Ç°»ç¾ç

¼¼ºÎ»çÇ×
³» ¿ë
Test Standard (½ÃÇè ±Ô°Ý)
JIS-B-9921 (1997), ASTM-F649-01, ASTM-F328-98
(NIST traceable)
Light source (±¤¿ø)
Laser diode (>100,000 hours)
Sensitivity (°¨µµ)
0.3 ¥ìm
Size Range (»çÀÌÁî ¹üÀ§)
0.3 ¥ìm ~ 25 ¥ìm
Channels (ä³Î)
3 channels(Choose from 0.3 ¥ìm, 0.5 ¥ìm, 0.7 ¥ìm, 1.0 ¥ìm, 2.0
¥ìm, 2.5 ¥ìm, 5 ¥ìm, 10 ¥ìm, 15 ¥ìm, 20 ¥ìm)
Counting Efficiency (°è¼ö È¿À²)
50¡¾20% @0.3¥ìm, 100¡¾10% @0.5¥ìm
Coincidence Loss (µ¿½Ã °è¼ö ¼Õ½Ç)
<5% @70,000 Particles/Liter or <5% @2,000,000 particles/ft3
Zero Count (Á¦·Î Ä«¿îÆ®)
<1 count per 5 minutes
Flow Rate (ÇÃ·Î¿ì ·¹ÀÌÆ®)
2.83 L /min (0.1cfm)
Sample time (»ùÇøµ ŸÀÓ)
User defined: (up to 59m59s) and auto repeat
(up to 99 times)
Count Limit Warning (ÇѰèÄ¡ °æ°í)
FED STD 209E (Class 1 to 100,000), ISO 14644-1 (Class 3 to
9), and user defined (custom)
Sampling Mode (»ùÇøµ ¸ðµå)
Cumulative, Differential, Number Concentration, Mass
Concentration and PM values
Error Indications (¿¡·¯ Ç¥½Ã)
Excess count limit, optics contamination, loss of laser power,
insufficient battery power
Interface (ÀÎÅÍÆäÀ̽º)
USB, Bluetooth
Internal Memory (³»ºÎ ¸Þ¸ð¸®)
6000 measurement data (6000 sets)
Power (Àü¿ø)
Li-ion polymer rechargeable battery (7.4V/5200mAH) or
9VDC1.5A AC Adapter (100~240V input)
Max. Operating Time (ÀÛµ¿ ½Ã°£)
Continuous operation > 8 hours with Li-ion battery
Dimensions (Å©±â)
93 (W) x 180 (H) x 48 (D) mm
Weight (¹«°Ô)
< 950 grams (including battery)
Environmental Conditions (ȯ°æ Á¶°Ç)
Operating: 5 ~ 45¡ÆC, < 90%RH,
Storage: -20 ~ 50¡ÆC, < 90%RH
Standard Accessories (±âº» ¾×¼¼¼­¸®)
Iso-kinetic probe, an AC charger, a USB cable, a CD with data
download software, user manual, carrying case,
zero count filter
Optional Accessories (¿É¼Ç ¾×¼¼¼­¸®)
Temperature, relative humidity, and pressure probes,
tripod mount, Bluetooth printer