Developed for vibration analysts, machine operators, and maintenance technicians. Easy to use, powerful for basic condition monitoring. Helps in maintaining machine reliability and verifying machinery repair. Store and trend condition data with Trend View.
• The only instrument to use for balancing, vibration, infrared, and high frequency sound in one compact, easy to use instrument.
• Powerful, inexpensive instrument to be used by vibration analyst, maintenance technician, or machniery operator.
• Smallest balancing instrument available, easy to carry.
• Use to verify machinery repair.
• PC-software for reports and trends is included.
|
|
|
|
|
|
|
|
VIBER X3¢â
Vibration transducer
|
Accelerometer
|
Standard nom 100 mV/g
|
(Selectable sensitivity in the instrument)
|
¡¾15%
|
Input amplitude range
|
Vibration
|
Max 50g RMS
|
With other sensor up to 500g and
|
Bearing condition
|
Max 5 gBC
|
Dynamic range
|
80 dB (156,08 Hz with auto ranging)
|
|
Frequency range
|
Vibration
|
2 - 400 Hz
|
User selectable
|
10 - 1000 Hz
|
6 - 1600 Hz
|
11 - 3200 Hz
|
Bearing condition
|
0,5 to 16 kHz
|
|
Vibration units
|
g-value, mm/s, m/s2, in/s, µm, mils
|
User selectable
|
Amplitude presentation
|
RMS, Peak, Peak-Peak
|
User selectable
|
Analysis
|
Five highest peaks can be displayed
|
VMI Trend Viewer Software included for PC
|
|
Frequency range
|
|
Frequency range of peak
|
2 - 400 Hz
|
User selectable unit,
|
detection
|
6 - 1600 Hz
|
between Hz and RPM
|
|
11 - 2000 Hz
|
|
|
10 - 1000 Hz
|
|
Storage Capacity
|
100 measurements can be stored
|
Three-point
|
10 balancing results can be stored
|
balancing
|
Communlcatlon
|
USB 2.0
|
interface
|
Sound frequency
|
60 Hz - 10 kHz
|
+26 dB to -4.1 dB
|
|
Filter enabled
|
500 Hz - 10 kHz
|
+26 dB to -4.1 dB
|
|
Temperature sensor
|
Built-in infrared sensor
|
|
Range
|
0 to 120 ¡É
|
|
Accuracy
|
Vibration
|
¡¾ 3 %
|
Full scale is 50g for acceleration
|
other units are frequency dependent.
|
Bearing condition
|
¡¾ 5 %
|
Over 0.03 gBC
|
Frequency/RPM
|
¡¾ 0.5 Hz/ ¡¾ 30 RPM
|
|
Temperature
|
¡¾ 1 ¡É
|
Emissivity factor must be set
|
in a accordance with the target surface
|
Battery
|
Rechargeable Lithium
|
2300 mA/h max 60¢ªC
|
Capacity of the batteries can
|
vary depending on hardware revision
|
Max 2300 mA/h
|
(Storage temp. -20¡ÆC to max 60¡ÆC)
|
Operating time
|
1 week normal use
|
Opering time depends on backlights.
|
volume level and batteries used.Backlights
|
adds 40mA and the sound volume up to
|
150mA. Charging time is approx:
|
6~12 hours.
|
External charger
|
5,0 V relugated @ 2000 mA
|
|
LCD display
|
B&W 64 x 120 pixels with
|
Operating temp. min 0 ¡ÆC to max 50 ¡ÆC
|
background light
|
storage temp,max 72 ¡É
|
Enclosure protection
|
IP 65
|
|
Operating temp. range
|
0 to 50¡ÆC
|
The restriction concerns display
|
Weight
|
415 gram
|
Instrument, including battery and
|
transducer
|
Size (L x W x H)
|