Logger Script
   
 
¼ÒÀ½°è, Áøµ¿°è
Á¶µµ°è,±¤·®°è,CHROMA METER,ÈÖµµ°è
Àϻ緮/±¤Åõ°úÀ² ÃøÁ¤±â
žçÀüÁö,ž籤¸ðµâ È¿À² ºÐ¼®±â
ȸÀü°è, ½ºÆ®·Îº¸½ºÄÚÇÁ
dz¼Ó°è,dz·®Ç³¼Ó°è,¿­¼±½Ädz·®Ç³¼Ó°è
¿Âµµ°è,¿Âµµ¼¾¼­,¿Â½Àµµ°è,³ëÁ¡°è,
µ¥ÀÌÅͱâ·Ï°è(µ¥ÀÌÅͷΰÅ)
WBGTÃøÁ¤±â,±â¾Ð°è
¹èÅ͸®Å×½ºÅÍ
ÀüÀÚÆÄ,Á¤Àü±â,°¡¿ì½º¸ÞŸ,Ç¥¸éÀúÇ×
Ķ¸®ºê·¹ÀÌÅÍ(CALIBRATOR)
»öÂ÷°è,ºÐ±¤±¤µµ°è,±¤Åðè,HAZE METER
ÆÄƼŬī¿îÅÍ(PARTICLE COUNTER),ºÐÁøÃøÁ¤±â
Àü±âÀüÀÚ°èÃø±â
´çµµ°è,¿°ºÐ°è,±¼Àý°è
»ê¾÷¿ë³»½Ã°æ
Çʸ§/À¯¸®Åõ°úÀ²ÃøÁ¤±â,UV±¤·®°è
µµ¸·µÎ²²ÃøÁ¤±â,ÃÊÀ½Æĵβ²ÃøÁ¤±â
°æµµ°è
¼öºÐÃøÁ¤±â
°¡½ºÃøÁ¤±â,³¿»õÃøÁ¤±â
¼öÁúÃøÁ¤±â
ÇÉȦŽÁö±â(Holiday Detector)
Ǫ½¬Ç®°ÔÀÌÁö,ÅټǸÞŸ,ÅäÅ©Å×½ºÅÍ
È®´ë°æ,¸¶ÀÌÅ©·Î½ºÄÚÇÁ,Á¶¸íÈ®´ë°æ
Àû¿Ü¼± ¿­È­»ó Ä«¸Þ¶ó
Å©·¢(±Õ¿­)ÃøÁ¤±â
À½ÀÌ¿ÂÃøÁ¤±â/¹æ»ç¼±·®ÃøÁ¤±â
ÃÊÀ½ÆÄŽ»ó±â
MIC Meter Industrial Company Á¦Ç°
REK Á¦Ç°
±âŸ
½ÅÁ¦Ç°
Ãßõ»óÇ°
°øµ¿ÁÖÅà °ü¸®±â±¸ Àåºñ
¹ýÁ¤µî·ÏÀåºñ(Çü½Ä½ÂÀÎÀåºñ)
HOME > Á¦Ç°¼Ò°³
 
VMI VIBER X3¢â Áøµ¿°è
 
Developed for vibration analysts, machine operators, and maintenance technicians. Easy to use, powerful for basic condition monitoring. Helps in maintaining machine reliability and verifying machinery repair. Store and trend condition data with Trend View.

• The only instrument to use for balancing, vibration, infrared, and high frequency sound in one compact, easy to use instrument.

• Powerful, inexpensive instrument to be used by vibration analyst, maintenance technician, or machniery operator.

• Smallest balancing instrument available, easy to carry.

• Use to verify machinery repair.

• PC-software for reports and trends is included.
 
 
 

 

 

VIBER X3¢â

 

 


 Vibration transducer

 Accelerometer

Standard nom 100 mV/g

(Selectable sensitivity in the instrument) 

¡¾15%

Input amplitude range

 Vibration

Max 50g RMS

With other sensor up to 500g and 

Bearing condition

Max   5 gBC 

 Dynamic range

80 dB (156,08 Hz with auto ranging)

 

 Frequency range

Vibration

2 - 400 Hz

User selectable 

10 - 1000 Hz

6 - 1600 Hz

11 - 3200 Hz

Bearing condition

0,5 to 16 kHz

 

 Vibration units

g-value, mm/s, m/s2, in/s, µm, mils

User selectable

 Amplitude presentation 

RMS, Peak, Peak-Peak

User selectable 

Analysis

Five highest peaks can be displayed

VMI Trend Viewer Software included for PC 

 

Frequency range

 

Frequency range of peak 

2 - 400 Hz

User selectable unit,

detection

6 - 1600 Hz

between Hz and RPM

 

11 - 2000 Hz

 

 

10 - 1000 Hz

 

Storage Capacity

100 measurements can be stored 

Three-point

10 balancing results can be stored

balancing

Communlcatlon 

USB 2.0 

interface

Sound frequency 

60 Hz - 10 kHz

+26 dB to -4.1 dB

 

Filter enabled

500 Hz - 10 kHz

+26 dB to -4.1 dB

 

Temperature sensor 

Built-in infrared sensor 

 

Range

 0 to 120 ¡É

 

 Accuracy

Vibration

¡¾ 3 %

Full scale is 50g for acceleration 

other units are frequency dependent.

 Bearing condition

 ¡¾ 5 %

 Over 0.03 gBC

Frequency/RPM

¡¾ 0.5 Hz/ ¡¾ 30 RPM 

 

 Temperature 

¡¾ 1 ¡É

Emissivity factor must be set

in a accordance with the target surface

 Battery

Rechargeable Lithium 

2300 mA/h max 60¢ªC

Capacity of the batteries can 

vary depending on hardware revision

 Max 2300 mA/h

(Storage temp. -20¡ÆC to max 60¡ÆC)

 Operating time

1 week normal use

Opering time depends on backlights.

volume level and batteries used.Backlights 

adds 40mA and the sound volume up to

150mA. Charging time is approx:

6~12 hours.

 External charger

 5,0 V relugated @ 2000 mA

 

 LCD display

 B&W 64 x 120 pixels with

Operating temp. min 0 ¡ÆC to max 50 ¡ÆC

background light

storage temp,max 72 ¡É

Enclosure protection

IP 65

 

 Operating temp. range

0 to 50¡ÆC

The restriction concerns display 

 Weight

415 gram

 Instrument, including battery and 

 transducer

 Size (L x W x H)

165mm x 80mm x 50mm