Logger Script
   
 
¼ÒÀ½°è, Áøµ¿°è
Á¶µµ°è,±¤·®°è,CHROMA METER,ÈÖµµ°è
Àϻ緮/±¤Åõ°úÀ² ÃøÁ¤±â
žçÀüÁö,ž籤¸ðµâ È¿À² ºÐ¼®±â
ȸÀü°è, ½ºÆ®·Îº¸½ºÄÚÇÁ
dz¼Ó°è,dz·®Ç³¼Ó°è,¿­¼±½Ädz·®Ç³¼Ó°è
¿Âµµ°è,¿Âµµ¼¾¼­,¿Â½Àµµ°è,³ëÁ¡°è,
µ¥ÀÌÅͱâ·Ï°è(µ¥ÀÌÅͷΰÅ)
WBGTÃøÁ¤±â,±â¾Ð°è
¹èÅ͸®Å×½ºÅÍ
ÀüÀÚÆÄ,Á¤Àü±â,°¡¿ì½º¸ÞŸ,Ç¥¸éÀúÇ×
Ķ¸®ºê·¹ÀÌÅÍ(CALIBRATOR)
»öÂ÷°è,ºÐ±¤±¤µµ°è,±¤Åðè,HAZE METER
ÆÄƼŬī¿îÅÍ(PARTICLE COUNTER),ºÐÁøÃøÁ¤±â
Àü±âÀüÀÚ°èÃø±â
´çµµ°è,¿°ºÐ°è,±¼Àý°è
»ê¾÷¿ë³»½Ã°æ
Çʸ§/À¯¸®Åõ°úÀ²ÃøÁ¤±â,UV±¤·®°è
µµ¸·µÎ²²ÃøÁ¤±â,ÃÊÀ½Æĵβ²ÃøÁ¤±â
°æµµ°è
¼öºÐÃøÁ¤±â
°¡½ºÃøÁ¤±â,³¿»õÃøÁ¤±â
¼öÁúÃøÁ¤±â
ÇÉȦŽÁö±â(Holiday Detector)
Ǫ½¬Ç®°ÔÀÌÁö,ÅټǸÞŸ,ÅäÅ©Å×½ºÅÍ
È®´ë°æ,¸¶ÀÌÅ©·Î½ºÄÚÇÁ,Á¶¸íÈ®´ë°æ
Àû¿Ü¼± ¿­È­»ó Ä«¸Þ¶ó
Å©·¢(±Õ¿­)ÃøÁ¤±â
À½ÀÌ¿ÂÃøÁ¤±â/¹æ»ç¼±·®ÃøÁ¤±â
ÃÊÀ½ÆÄŽ»ó±â
MIC Meter Industrial Company Á¦Ç°
REK Á¦Ç°
±âŸ
½ÅÁ¦Ç°
Ãßõ»óÇ°
°øµ¿ÁÖÅà °ü¸®±â±¸ Àåºñ
¹ýÁ¤µî·ÏÀåºñ(Çü½Ä½ÂÀÎÀåºñ)
HOME > Á¦Ç°¼Ò°³
 
PIE235 pH & Voltage Process Calibrator
 
- Technician friendly operation
- Calibrate with Confidence
- Source three ranges of mV & V dc plus percent of 1 to 5 volts
- Power your loops with over 1,000 Ohm loads
- Read DC volts
- Save time calibrating recorders and monitors in 4 to 20 mA loops
- Simulate pH probes into transmitters & analyzers
- Quickly set any three outputs plus automatic stepping & ramping
- Designed for you by experienced calibrator manufacturers


* Altek 334/Altek 334A ´ëüǰ
 
 
 

Altek235(´ÜÁ¾)ÀÇ ´ëü¸ðµ¨

PIE 235 vs Altek 235 Discontinued - Suggested replacement PIE 235

Á¦Ç°»ç¾ç ¹× ±â¼úÀû ¼¼ºÎ»çÇ×

General
Operating Temperature Range -20 to 60 ¡ÆC (-5 to 140 ¡ÆF)
Storage Temperature Range -30 to 60 ¡ÆC (-22 to 140 ¡ÆF)
Temperature effect ¡Â ¡¾ 0.005 %/¡ÆC of Full Scale
Relative Humidity Range 10 % ¡ÂRH ¡Â90 % (0 to 35 ¡ÆC), Non-condensing
10 % ¡ÂRH¡Â 70 % (35 to 60 ¡ÆC), Non-condensing
Common Mode Rejection 50/60 Hz, 100 dB
Normal Mode Rejection 50/60 Hz, 50 dB
Noise ¡Â ¡¾ ¨ö Least Significant Digit from 0.1 to 10 Hz
Size 5.63 x 3.00 x 1.60 in, 143 x 76 x 41mm (L x W x H)
Weight 12.1 ounces, 0.34 kg (including boot & batteries)
Batteries Four ¡°AA¡± Alkaline 1.5V (LR6)
Battery Life Four ¡°AA¡± Alkaline 1.5V (LR6)
Low Battery Low battery indication with nominal 1 hour of
operation left
Protection against
misconnection
Over-voltage protection to 60 vrms (rated for 30
seconds). Red LED and audible alarm indicates
OVERLOAD for out of range conditions.
Display High contrast graphic liquid crystal display with
0.35¡± (9 mm) high digits on main & 0.2¡± (5 mm) on
mA display. LED backlighting for use in low lit areas.
Voltage Source
Ranges and Resolution Accuracy
-500.00 to 999.00 mV ¡Â ¡¾ (0.02 % of Reading + 0.01% of Full Scale)
1.000 to 5.000 V ¡Â ¡¾ (0.02 % of Reading + 0.002 V)
0.000 to 20.000 V ¡Â ¡¾ (0.02 % of Reading + 0.01% of Full Scale)
-25.0 to 125.0% of 1 to 5 V ¡Â ¡¾ 0.1%
Source Current ¡Ã 20 mA
Sink Current > 16 mA
Output Impedance ¡Â 0.3 Ohm at ¡Â 20 mA load
Short Circuit Duration Infinite
Voltage Read
Ranges and Resolution Accuracy
-500.00 to 999.00 mV ¡Â ¡¾ (0.02 % of Reading + 0.01% of Full Scale)
1.000 to 5.000 V ¡Â ¡¾ (0.02 % of Reading + 0.002 V)
0.000 to 20.000 V ¡Â ¡¾ (0.02 % of Reading + 0.01% of Full Scale)
-25.0 to 125.0% of 1 to 5 V ¡Â ¡¾ 0.1%
0.00 to 60.00 V ¡Â ¡¾ (0.02 % of Reading + 0.02 V)
Input resistance ¡Ã 1 M¥Ø
pH Source
Accuracy in mV ¡Â ¡¾ (0.02 % of Reading in mV + 0.1 mV)
Accuracy in pH ¡Â ¡¾ 0.003 pH @ 25¡ÆC