Logger Script
   
 
¼ÒÀ½°è, Áøµ¿°è
Á¶µµ°è,±¤·®°è,CHROMA METER,ÈÖµµ°è
Àϻ緮/±¤Åõ°úÀ² ÃøÁ¤±â
žçÀüÁö,ž籤¸ðµâ È¿À² ºÐ¼®±â
ȸÀü°è, ½ºÆ®·Îº¸½ºÄÚÇÁ
dz¼Ó°è,dz·®Ç³¼Ó°è,¿­¼±½Ädz·®Ç³¼Ó°è
¿Âµµ°è,¿Âµµ¼¾¼­,¿Â½Àµµ°è,³ëÁ¡°è,
µ¥ÀÌÅͱâ·Ï°è(µ¥ÀÌÅͷΰÅ)
WBGTÃøÁ¤±â,±â¾Ð°è
¹èÅ͸®Å×½ºÅÍ
ÀüÀÚÆÄ,Á¤Àü±â,°¡¿ì½º¸ÞŸ,Ç¥¸éÀúÇ×
Ķ¸®ºê·¹ÀÌÅÍ(CALIBRATOR)
»öÂ÷°è,ºÐ±¤±¤µµ°è,±¤Åðè,HAZE METER
ÆÄƼŬī¿îÅÍ(PARTICLE COUNTER),ºÐÁøÃøÁ¤±â
Àü±âÀüÀÚ°èÃø±â
´çµµ°è,¿°ºÐ°è,±¼Àý°è
»ê¾÷¿ë³»½Ã°æ
Çʸ§/À¯¸®Åõ°úÀ²ÃøÁ¤±â,UV±¤·®°è
µµ¸·µÎ²²ÃøÁ¤±â,ÃÊÀ½Æĵβ²ÃøÁ¤±â
°æµµ°è
¼öºÐÃøÁ¤±â
°¡½ºÃøÁ¤±â,³¿»õÃøÁ¤±â
¼öÁúÃøÁ¤±â
ÇÉȦŽÁö±â(Holiday Detector)
Ǫ½¬Ç®°ÔÀÌÁö,ÅټǸÞŸ,ÅäÅ©Å×½ºÅÍ
È®´ë°æ,¸¶ÀÌÅ©·Î½ºÄÚÇÁ,Á¶¸íÈ®´ë°æ
Àû¿Ü¼± ¿­È­»ó Ä«¸Þ¶ó
Å©·¢(±Õ¿­)ÃøÁ¤±â
À½ÀÌ¿ÂÃøÁ¤±â/¹æ»ç¼±·®ÃøÁ¤±â
ÃÊÀ½ÆÄŽ»ó±â
MIC Meter Industrial Company Á¦Ç°
REK Á¦Ç°
±âŸ
½ÅÁ¦Ç°
Ãßõ»óÇ°
°øµ¿ÁÖÅà °ü¸®±â±¸ Àåºñ
¹ýÁ¤µî·ÏÀåºñ(Çü½Ä½ÂÀÎÀåºñ)
HOME > Á¦Ç°¼Ò°³
 
PIE901 mA&Volatage Precess Calibrator
 
- Easy to read
- Troubleshoot loop problems
- Source milliamps
- Automatic output stepping & ramping
- Calibrate using loop power
- Read loop current
- Power & measure 2 wire transmitters
- Source & Read DC volts
- Easily measure pressure with a plug in pressure module
 
 
 

Á¦Ç°»ç¾ç ¹× ±â¼úÀû ¼¼ºÎ»çÇ×

General
Operating Temperature Range -20 to 60 ¡ÆC (-5 to 140 ¡ÆF)
Storage Temperature Range -30 to 60 ¡ÆC (-22 to 140 ¡ÆF)
Relative Humidity Range 10 % ¡ÂRH ¡Â90 % (0 to 35 ¡ÆC), Non-condensing
10 % ¡ÂRH¡Â 70 % (35 to 60 ¡ÆC), Non-condensing
Size 5.63 x 3.00 x 1.60 in, 143 x 76 x 41mm (LxWxH)
Weight 12.1 ounces, 0.34 kg (including boot & batteries)
Battery Four ¡°AA¡± Alkaline 1.5V (LR6)
Optional AC Adaptors 100 to 240 VAC to 9V USB C (020-0104)
Optional Rechargeable Batteries  (4) NiMH ¡°AA¡± Batteries (020-0105)
Low Battery Continuous indication of battery level with
nominal 1 hour of operation left with low battery
Protection against misconnection Over-voltage protection to 135 vrms (rated for
30 seconds) or 240 vrms (rated for 15 seconds)
Display TFT color display with LED backlighting. Dark
Mode for use in bright sunlight
Read mA
Ranges and Resolution 0.000 to 24.000 mA, -25.00 to 125.00% of 4-20 mA
Accuracy ¡Â ¡¾ (0.01 % of Reading +0.002 mA)
Voltage burden ¡Â 2V at 50 mA
Overload/Current limit protection 25 mA nominal
Voltage Read
Ranges  -60.000 to +60.000 VDC
Accuracy ¡Â ¡¾ (0.02 % of Reading + 0.01% Full Scale)
Temperature effect ¡Â ¡¾ 100 ppm/¡ÆC of FS
Input resistance ¡Ã 2 M¥Ø
Source/Power & Measure Two Wire Transmitters
Ranges and Resolution 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA
Accuracy ¡Â ¡¾ (0.01 % of Reading +0.002 mA)
Noise ¡Â ¡¾ ¨ö Least Significant Digit
Temperature effect ¡Â ¡¾ 0.005 %/¡ÆC of FS
Loop compliance voltage ¡Ã 24 DCV @ 20.00mA
Loop drive capability - Leak
Detection Off
1200 ¥Ø at 20 mA
950 ¥Ø with Hart Resistor enabled
Loop drive capability - Leak
Detection On
1000 ¥Ø at 20 mA
750 ¥Ø with Hart Resistor enabled
2-Wire Transmitter Simulation
Accuracy Same as Source/Power & Measure
Voltage burden ¡Â 2V at 20 mA
Overload/Current limit protection 24 mA nominal
Loop voltage limits 2 to 60 VDC (fuse-less protected from reverse
polarity connections
Source V dc
Ranges and Resolution 0.000 to 22.500V
Accuracy ¡Â ¡¾ (0.02 % of Reading + 0.01% Full Scale)
Source Current ¡Ã 20 mA
Sink Current > 16 mA
Output Impedance < 0.05 Ohm