Logger Script
   
 
¼ÒÀ½°è, Áøµ¿°è
Á¶µµ°è,±¤·®°è,CHROMA METER,ÈÖµµ°è
Àϻ緮/±¤Åõ°úÀ² ÃøÁ¤±â
žçÀüÁö,ž籤¸ðµâ È¿À² ºÐ¼®±â
ȸÀü°è, ½ºÆ®·Îº¸½ºÄÚÇÁ
dz¼Ó°è,dz·®Ç³¼Ó°è,¿­¼±½Ädz·®Ç³¼Ó°è
¿Âµµ°è,¿Âµµ¼¾¼­,¿Â½Àµµ°è,³ëÁ¡°è,
µ¥ÀÌÅͱâ·Ï°è(µ¥ÀÌÅͷΰÅ)
WBGTÃøÁ¤±â,±â¾Ð°è
¹èÅ͸®Å×½ºÅÍ
ÀüÀÚÆÄ,Á¤Àü±â,°¡¿ì½º¸ÞŸ,Ç¥¸éÀúÇ×
͏®ºê·¹ÀÌÅÍ(CALIBRATOR)
»öÂ÷°è,ºÐ±¤±¤µµ°è,±¤Åðè,HAZE METER
ÆÄƼŬī¿îÅÍ(PARTICLE COUNTER),ºÐÁøÃøÁ¤±â
Àü±âÀüÀÚ°èÃø±â
´çµµ°è,¿°ºÐ°è,±¼Àý°è
»ê¾÷¿ë³»½Ã°æ
Çʸ§/À¯¸®Åõ°úÀ²ÃøÁ¤±â,UV±¤·®°è
µµ¸·µÎ²²ÃøÁ¤±â,ÃÊÀ½ÆÄµÎ²²ÃøÁ¤±â
°æµµ°è
¼öºÐÃøÁ¤±â
°¡½ºÃøÁ¤±â,³¿»õÃøÁ¤±â
¼öÁúÃøÁ¤±â
ÇÉȦŽÁö±â(Holiday Detector)
Ǫ½¬Ç®°ÔÀÌÁö,ÅټǸÞŸ,ÅäÅ©Å×½ºÅÍ
È®´ë°æ,¸¶ÀÌÅ©·Î½ºÄÚÇÁ,Á¶¸íÈ®´ë°æ
Àû¿Ü¼± ¿­È­»ó Ä«¸Þ¶ó
Å©·¢(±Õ¿­)ÃøÁ¤±â
À½ÀÌ¿ÂÃøÁ¤±â/¹æ»ç¼±·®ÃøÁ¤±â
ÃÊÀ½ÆÄŽ»ó±â
MIC Meter Industrial Company Á¦Ç°
REK Á¦Ç°
±âŸ
½ÅÁ¦Ç°
Ãßõ»óǰ
°øµ¿ÁÖÅà °ü¸®±â±¸ Àåºñ
¹ýÁ¤µî·ÏÀåºñ(Çü½Ä½ÂÀÎÀåºñ)
HOME > Á¦Ç°¼Ò°³
 
TES-1339R µðÁöÅÐÁ¶µµ°è
 
- Dual Display 4-digit LCD Reading
- Spectral Sensitivity close to CIE photopic Curve
- ÃøÁ¤ ¹üÀ§ : 0.01 ¡­ 999900 Lux, 0.001 ¡­ 99990 Fc,
Autoranging 5 step
- ³ôÀº Á¤È®¼º / ºü¸¥ ¹ÝÀÀ¼Óµµ
- Integral Illuminance(´©°èÁ¶µµ) ÃøÁ¤
- Luminous Intensity(±¤µµ) ÃøÁ¤
- Data Hold function
- Data ÀúÀå / ºÒ·¯¿À±â ±â´É
- Data logger function
- Reference value setting for relative or percentage
deviation measurement
- Ripple measurement for STRAY + LIGHT function
- Time-hold function
- Point Average function
- Comparator function
- ÀÚµ¿ ²¨Áü ±â´É
- RS-232 Interface
- CNS 5119 Class ¥± <´ë¸¸ ±¹°¡ Ç¥ÁØ>


-Á¶´Þû ¹°Ç° ¸ñ·Ï ¹øÈ£ : 41115309-22300729
-Á¶´Þû ¹°Ç° ºÐ·ù ¹øÈ£ : 41115309
-Á¶´Þû ¹°Ç° ½Äº° ¹øÈ£ : 22300729
 
 
 
Á¦ ǰ »ç ¾ç
 
¼¼ºÎ»çÇ×
³» ¿ë
Ç¥½Ã
Dual display, 4 digit LCD reading
ÃøÁ¤ ¹üÀ§ / ºÐÇØ´É
lux
ÃøÁ¤¹üÀ§
ºÐÇØ´É
99.99 lux
0.01
999.9 lux
0.1
9999 lux
1
99990 lux
10
999900 lux
100
fc
9.999 fc
0.001
99.99 fc
0.01
999.9 fc
0.1
9999 fc
1
99990 fc
10
´ÜÀ§ º¯È¯
1fc = 10.76 lux
Overrange Ç¥½Ã
ÃøÁ¤°ªÀÌ ÃøÁ¤ ¹üÀ§º¸´Ù ³ôÀ» ¶§ ¡®OL¡¯ Ç¥½Ã
Á¤È®µµ
¡¾3% rdg ¡¾5digits
CIE photopic f'1
6%
Temperature characteristics
¡¾0.1%/¡É
Measuring rate
¾à 5 time/sec
Photosensor
Silicon photodiodes
Data Memory Capacity
99sets(Direct reading from LCD display)
Data Logger Capacity
40000 sets
ÀÚµ¿ÀúÀå Interval time
3ÃÊ¡­180ÃÊ
»ç¿ë ¿Âµµ/½Àµµ
0¡É¡­40¡É / 80% RH ÀÌÇÏ
º¸°ü ¿Âµµ/½Àµµ
-10¡É¡­50¡É / 70% RH ÀÌÇÏ
Àü¿ø/¼ö¸í
1.5V 6pcs Battery / 100½Ã°£(Carbon Zinc)
Photosensor Lead length
¾à 150cm
Æ÷Åä¼¾¼­Å©±â
92(L)¡¿60(W)¡¿29(H)mm
Dimension
150(L)¡¿72(W)¡¿35(H)mm
¹«°Ô
320g
±âº»¾Ç¼¼»ç¸®
»ç¿ë¼³¸í¼­, Battery, Carrying Case, Software CD,RS-232 Cable
¿É¼Ç¾Ç¼¼»ç¸®
AC Adaptor, »ï°¢´ë, USB Cable(PC¿¡ RS-232 Port(9 Pin)¸¦ ÀåÂøÇÒ ¼ö ¾øÀ» °æ¿ì »ç¿ë)